-
Research Reports in Clinical Cardiology
- About Dovepress
Open access peer-reviewed scientific and medical journals.
- Open Access
Dove Medical Press is now a member of the Open Access Initiative
- An Author's Guide
A guide to help authors get their paper published.
- Advocacy
Support Open Access and Dove Press
- Reprints
Promotional Article Monitoring - further details
- Favored Author Program
Real benefits for authors, including fast-track processing of papers.
Response of the oxygen pulse during exercise in children with atrial repair for transposition of the great arteries
Original Research
(2531) Total Article Views
Authors: Buys R, Dockx K, Gewillig M, Reybrouck T
Published Date November 2012 Volume 2012:3 Pages 57 - 62
DOI: http://dx.doi.org/10.2147/RRCC.S33328
Received: | 26 April 2012 |
---|---|
Accepted: | 22 June 2012 |
Published: | 30 November 2012 |
1Department of Rehabilitation Sciences, 2Department of Cardiovascular Rehabilitation, University of Leuven, Leuven, Belgium; 3Department of Pediatric Cardiology, University Hospital Gasthuisberg, Leuven, Belgium
*These authors contributed equally to this paper
Background: The oxygen pulse equals stroke volume times arterial–venous oxygen difference and is calculated by dividing oxygen uptake (VO2) by heart rate (HR). In children with a Senning repair for the transposition of the great arteries (TGA), the response of both HR and VO2 to exercise is impaired. Our aim was to assess the oxygen pulse response during exercise in patients who underwent a Senning operation, comparing it with healthy controls.
Methods: Twenty-one children with a Senning repair (mean age 12.5 ± 1.7 years) and a control group of 31 healthy children (mean age 13.2 ± 2.0 years) performed a graded maximal exercise test on a treadmill, during which HR and VO2 were measured. Oxygen pulse was calculated by dividing VO2 by HR. Right ventricular function was quantitatively assessed by cardiac ultrasound.
Results: Senning patients had a lower peak oxygen pulse than the control (P = 0.0024) (8.45 ± 1.90 mL • beats-1 versus 11.7 ± 3.93 mL • beats-1), as with the peak VO2 (P < 0.001) (35.8 ± 5.67 mL • min-1 • kg-1 versus 46.6 ± 8.02 mL • min-1 • kg-1) and peak HR (171 ± 14 beats • min-1 versus 188 ± 11 beats • min-1). During submaximal exercise, oxygen pulse and VO2 were also significantly lower in Senning patients when compared to the control group (P = 0.027). In seven Senning patients (33%), the oxygen pulse did not increase any further after the first exercise levels. These patients had lower right ventricular function compared to the control group (P = 0.04).
Conclusion: Children with a Senning repair for TGA have a reduced peak VO2, peak HR, and peak oxygen pulse. Their oxygen pulse starts off at a lower level, reaches its plateau earlier, and is related to right ventricular function. This variable can be considered a complementary parameter to assess cardiovascular exercise performance.
Keywords: transposition of the great arteries, Senning repair, oxygen pulse, cardiopulmonary exercise testing
Post to:
Cannotea Citeulike Del.icio.us Facebook LinkedIn Twitter
Readers of this article also read:
- ACC 2014
We will attend the 2014 American College of Cardiology Scientific Session and Expo (ACC) on March 29-31, 2014. Stop by booth 3217 to talk with us.
- The western diet and lifestyle and diseases of civilization
- Aldosterone and aldosterone receptor antagonists in patients with chronic heart failure
- Everolimus-eluting stents in interventional cardiology
- Transitioning from population to individualized preventive cardiology