SHORT COMMUNICATION
Year : 2009  |  Volume : 71  |  Issue : 1  |  Page : 72-74
HPTLC method for the simultaneous estimation of valsartan and hydrochlorothiazide in tablet dosage form


1 Shri B. M. Shah College of Pharmaceutical Education & Research, Modasa-383 315, India
2 L. M. College of Pharmacy, Navrangpura, Ahmedabad-380 009, India

Date of Submission 08-Aug-2006
Date of Decision 19-Jul-2008
Date of Acceptance 03-Feb-2009
Date of Web Publication 8-Jun-2009

Correspondence Address:
N J Shah
Shri B. M. Shah College of Pharmaceutical Education & Research, Modasa-383 315
India
Login to access the Email id


DOI: 10.4103/0250-474X.51967

PMID: 20177464

Get Permissions

   Abstract  

A simple, precise, accurate and rapid high performance thin layer chromatographic method has been developed and validated for the simultaneous estimation of valsartan and hydrochlorothiazide in combined dosage forms. The stationary phase used was precoated silica gel 60F 254 . The mobile phase used was a mixture of chloroform: methanol: toluene: glacial acetic acid (6:2:1:0.1 v/v/v/v). The detection of spots were carried out at 260 nm. The method was validated in terms of linearity, accuracy, precision and specificity. The calibration curve was found to be linear between 300 to 800 ng/spot for valsartan and 100 to 600 ng/spot for hydrochlorothiazide. The limit of detection and the limit of quantification for the valsartan were found to be 100 and 300 ng/spot respectively and for hydrochlorothiazide 30 and 100 ng/spot respectively. The proposed method can be successfully used to determine the drug content of marketed formulation.


Keywords: Valsartan, hydrochlorothiazide, simultaneous estimation, HPTLC


How to cite this article:
Shah N J, Suhagia B N, Shah R R, Patel N M. HPTLC method for the simultaneous estimation of valsartan and hydrochlorothiazide in tablet dosage form. Indian J Pharm Sci 2009;71:72-4

How to cite this URL:
Shah N J, Suhagia B N, Shah R R, Patel N M. HPTLC method for the simultaneous estimation of valsartan and hydrochlorothiazide in tablet dosage form. Indian J Pharm Sci [serial online] 2009 [cited 2014 Mar 5];71:72-4. Available from: http://www.ijpsonline.com/text.asp?2009/71/1/72/51967


Valsartan, a nonpeptide, is N -(1-oxopentyl)- N -[[2'-(1 H -tetrazol-5-yl) [1,1'-biphenyl]-4-yl] methyl]-L-valine [1] . Hydrochlorothiazide is 6-chloro-3,4-dihydro-2H-1, 2, 4-benzothiadiazine-7-sulphonamide, 1, 1-dioxide. In patients with moderate hypertension, first-line therapy with the fixed-dose of valsartan/hydrochlorothiazide combination leads to BP normalization with high response rates. Literature survey revealed that a few HPLC and spectrophotometry methods are reported for the estimation of valsartan in biological samples such as plasma [2],[3],[4],[5],[6],[7] . So far no HPTLC method has been reported for the estimation of valsartan and hydrochlorothiazide in combined dosage forms. In the present investigation, an accurate and precise HPTLC method for the simultaneous estimation of valsartan and hydrochlorothiazide in combined dosage forms has been developed.

Valsartan and hydrochlorothiazide standard were procured as a gift sample from Jubilant Organosys Ltd., Mysore, India. Silica gel 60F 254 TLC plates (10×10 cm, layer thickness 0.2 mm, E. Merck, Mumbai, India) were used as a stationary phase. All chemicals and reagents used were of analytical grade. Tablets containing valsartan (80 mg) and hydrochlorothiazide (12.5 mg) were procured from the local pharmacy (Valzarr-H, Torrent Pharmaceutical Ltd, Ahmedabad, India). A Camag HPTLC system comprising of Camag Linnomate V automatic sample applicator, Hamilton syringe (100 µl), Camag TLC Scanner 3, Camag WinCATS software, Camag Twin-trough chamber (10×10 cm) and ultrasonicator were used during study.

Valsartan and hydrochlorothiazide (25 mg) each were weighed accurately, dissolved and diluted with methanol to obtain the final concentration of 100 µg/ml of each drug. Twenty tablets were weighed accurately and ground to a fine powder. Weight equivalent to 25 mg of valsartan and hydrochlorothiazide were transferred to conical flask and mixed with methanol. The solution was sonicated for 15 min. The extracts were filtered through Whatman filter paper No. 41 and residue was washed thoroughly with methanol. The extracts and washing were pooled and transferred to a 250 ml volumetric flask and volume was made up to 250 ml with methanol. Required dilutions were made to get 100 µg/ml of valsartan and hydrochlorothiazide.

TLC plates were prewashed with methanol. Activation of plates was done in an oven at 50 0 for 5 min. The chromatographic conditions maintained were precoated silica gel 60F 254 aluminum sheets (10×10 cm) as stationary phase, chloroform:methanol:toluene:glacial acetic acid (6:2:1:0.1 v/v/v/v) as mobile phase, chamber and plate saturation time of 30 min, migration distance allowed was 72 mm, wavelength scanning was done at 260 nm keeping the slit dimensions at 5×0.45 mm. A deuterium lamp provided the source of radiation. Standard solutions of valsartan and hydrochlorothiazide were spotted and developed. Photometric measurements were performed at 260 nm in reflectance mode with Camag TLC scanner 3 using WinCATS software.

Aliquots of 3.0, 4.0, 5.0, 6.0, 7.0, 8.0 µl of standard solution of valsartan and 1.0, 2.0, 3.0, 4.0, 5.0, 6.0 µl of hydrochlorothiazide were applied on the TLC plate (100 µg/ml of drug). TLC plate was dried, developed and analyzed photometrically as described earlier. The standard calibration curve was generated using regression analysis with Microsoft excel. Sample solutions of the marketed formulation were spotted on to the same plate followed by development scanning. The analysis was repeated in triplicate. The content of the drug was calculated from the peak areas recorded. The developed method was validated in terms of linearity, accuracy, limit of detection, limit of quantification, intra-day and inter-day precision and repeatability of measurement as well as repeatability of sample application [8] .

A solvent system that would give dense and compact spots with significant R f values were desired for quantification of valsartan and hydrochlorothiazide in pharmaceutical formulations. The mobile phase consisting of chloroform:methanol:toluene:glacial acetic acid (6:2:1:0.1 v/v/v/v) gave R f values of 0.36±0.04 and 0.63±0.03 for valsartan and hydrochlorothiazide, respectively [Figure 1]. The linear regression data (n=5, [Table 1]) showed a good linear relationship over a concentration range of 300-800 ng/spot and 100-600 ng/spot for valsartan and hydrochlorothiazide, respectively. The limit of detection and limit of quantification for valsartan was found to be 100 and 300 ng/spot and for hydrochlorothiazide, 30 and 100 ng/spot, respectively.

The intra-day precision was determined by analyzing standard solutions in the concentration range of 400 ng/spot to 700 ng/spot for valsartan and 200 ng/spot to 500 ng/spot for hydrochlorothiazide for 3 times on the same day while inter-day precision was determined by analyzing corresponding standards daily for 3 day over a period of one week. The intra-day and inter-day coefficients of variation for both drugs were found to be in the range of 0.27-1.19% and 0.12-1.05%, respectively. These values indicate that the method is precise.

Repeatability of sample application was assessed by spotting 4 µl of drug solution 5 times on a TLC plate followed by development of plate and recording the peak area for 5 spots. The % RSD for peak area values of valsartan and hydrochlorothiazide were found to be 0.98 and 0.83, respectively. Repeatability of measurement of peak area was determined by spotting 4 µl of valsartan and hydrochlorothiazide solution on a TLC plate and developing the plate. The separated spot was scanned five times without changing the position of the plate and % RSD for measurement of peak area of valsartan and hydrochlorothiazide were found to be 0.43 and 0.49, respectively. To confirm the specificity of the proposed method, the solution of the formulation was spotted on the TLC plate, developed and scanned. It was observed that the excipients present in the formulation did not interfere with the peaks of valsartan and hydrochlorothiazide.

Recovery studies of the drugs were carried out for the accuracy parameter. These studies were carried out at three levels i.e. multiple level recovery studies. Sample stock solutions from tablet formulation of 100 µg/ml were prepared. Dilutions were made and recovery studies were performed. Percentage recovery was found to be within the limits as listed in [Table 2]. The assay value for the marketed formulation was found to be within the limits as listed in [Table 2]. The low RSD value indicated the suitability of the method for routine analysis of valsartan and hydrochlorothiazide in pharmaceutical dosage forms.

The developed HPTLC technique is simple, precise, specific and accurate and the statistical analysis proved that method is reproducible and selective for the analysis of valsartan and hydrochlorothiazide in bulk drug and tablet formulations.


   Acknowledgements   Top


The authors are thankful to Jubilant Organosys Ltd., Mysore for the gift sample of valsartan and hydrochlorothiazide. Authors are thankful to Principal and management for providing necessary facilities and encouragement.

 
   References   Top

1. Goodfriend TL, Elliott ME, Catt KJ. Angiotensin receptors and their antagonists. N Eng J Med 1996;334:1649.   Back to cited text no. 1    
2. Noriko D, Richard ZL, Fakhreddin J. Analytical Technologies in the Biomedical and Life Sciences, High-performance liquid chromatographic analysis of angiotensin II receptor antagonist valsartan using a liquid extraction method. J Chromatogr B 2002;766:345.  Back to cited text no. 2    
3. Eda S, Sadi A, Nilgun GG, Sibel AO, Zuhre S. Simultaneous determination of valsartan and hydrochlorothiazide in tablets by first-derivative ultraviolet spectrophotometry and LC. J Pharm Biomed Anal 2001;25:1009.   Back to cited text no. 3    
4. Eric F, Alexander D, Paul R. Development and validation of chiral high-performance liquid chromatographic methods for the quantitation of valsartan and of the tosylate of valinebenzyl ester. J Chromatogr B Biomed Sci Appl 1996;686:77.   Back to cited text no. 4    
5. Gonzalez L, Lopez JA, Alonso RM, Jimenez RM. A Fast screening method for the determination of angiotensin II receptor antagonists in human plasma by high-performance liquid chromatography with fluorimetric detection. J Chromatogr A 2002;949:49.   Back to cited text no. 5    
6. Macek J, Klima J, Ptacek P. Rapid determination of valsartan in human plasma by protein precipitation and high-performance liquid chromatography. J Chromatogr B Anal Technol Biomed Life Sci 2006;832:169.   Back to cited text no. 6    
7. Tatar S, Saglik S. Comparison of UV- and second derivative-spectrophotometric and LC methods for the determination of valsartan in pharmaceutical formulation. J Pharm Biomed Anal 2002;30:371.  Back to cited text no. 7    
8. ICH. Q2B Validation of analytical procedure: Methodology. International Conference on Harmonization, Geneva; 1996 March.  Back to cited text no. 8    


    Figures

  [Figure 1]
 
 
    Tables

  [Table 1], [Table 2]

This article has been cited by
1 Development and Validation of Spectrophotometric Methods for Simultaneous Estimation of Valsartan and Hydrochlorothiazide in Tablet Dosage Form
Monika L. Jadhav,Manoj V. Girase,Shripad K. Tidme,Manish S. Junagade
International Journal of Spectroscopy. 2014; 2014: 1
[Pubmed]
2 Analysis of Sartans: A Review
Izabela Muszalska,Agnieszka Sobczak,Agnieszka Dolhan,Anna Jelinska
Journal of Pharmaceutical Sciences. 2013; : n/a
[Pubmed]
3 Simultaneous determination of valsartan and hydrochlorothiazide in their pharmaceutical formulations
Rezka, M.R., El Remalib, N.M., El Bayoumi Abdel Aleema, A.-A.
Der Pharma Chemica. 2012; 4(1): 529-537
[Pubmed]
4 Simultaneous estimation of valsartan and hydrochlorothiazide in fixed dose combination in UV spectrophotometry
Deshpande, M.M., Ahajan, M.P., Sawant, S.D.
International Journal of Pharmaceutical Sciences. 2012; 3(1): 235-240
[Pubmed]
5 HPLC method development for simultaneous estimation of Hydrochlorothiazide and perindropril in tablet dosage form
Sahoo, S., Panda, P.K., Mishra, S.K., Sahoo, S.
Asian Journal of Pharmaceutical and Clinical Research. 2012; 5(sup 2): 136-138
[Pubmed]
6 Validation of TLC densitometry for simultaneous quality and quantity analysis of angiotensin II receptor antagonists Losartan, Telmisartan and Valsartan
Tsvetkova, D., Obreshkova, D., Ognjanov, S.
Comptes Rendus de LæAcademie Bulgare des Sciences. 2011; 64(1): 39-44
[Pubmed]
7 Spectrophotometric estimation of valsartan and benazepril hydrochloride in pure and pharmaceutical formulations
Madhavi, L., Shireesha, M., Tuljarani, G.
International Journal of ChemTech Research. 2011; 3(4): 1830-1834
[Pubmed]
8 QUANTITATIVE SIMULTANEOUS DETERMINATION OF AMLODIPINE, VALSARTAN, AND HYDROCHLOROTHIAZIDE IN “EXFORGE HCT” TABLETS USING HIGH-PERFORMANCE LIQUID CHROMATOGRAPHY AND HIGH-PERFORMANCE THIN-LAYER CHROMATOGRAPHY
Susheel John Varghese, Thengungal Kochupappy Ravi
Journal of Liquid Chromatography & Related Technologies. 2011; 34(12): 981
[VIEW]
9 A validated stability indicating HPTLC method for simultaneous estimation of irbesartan and hydrochlorothiazide
Amol S. Khodke,Laxman V. Potale,Kailash G. Bothara,Mrinalini C. Damle
Pharmaceutical Methods. 2010; 1(1): 39
[Pubmed]
10 Stability-indicating UPLC method for determination of Valsartan and their degradation products in active pharmaceutical ingredient and pharmaceutical dosage forms
Ch. Krishnaiah,A. Raghupathi Reddy,Ramesh Kumar,K. Mukkanti
Journal of Pharmaceutical and Biomedical Analysis. 2010; 53(3): 483
[Pubmed]
11 Stability-indicating UPLC method for determination of Valsartan and their degradation products in active pharmaceutical ingredient and pharmaceutical dosage forms
Krishnaiah, C., Reddy, A.R., Kumar, R., Mukkanti, K.
Journal of Pharmaceutical and Biomedical Analysis. 2010; 53(3): 483-489
[Pubmed]
12 Thin layer chromatography (TLC) and video-scanning in a new method for the analysis of angiotensin AT 1 receptor antagonists, telmisartan and valsartan, in pharmaceuticals
Inglot, T., Gumieniczek, A., MacZka, P.
Annales Universitatis Mariae Curie-Sklodowska, Sectio DDD: Pharmacia. 2010; 23(4): 43-50
[Pubmed]



 

Top
Print this article  Email this article
 
  Search
   
   Next article
   Previous article 
   Table of Contents
  
    Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
 Related articles
    Article in PDF (451 KB)
    Citation Manager
    Access Statistics
    Reader Comments
    Email Alert *
    Add to My List *
* Registration required (free)  


    Abstract
    Acknowledgements
    References
    Article Figures
    Article Tables

 Article Access Statistics
    Viewed 2286    
    Printed 63    
    Emailed 4    
    PDF Downloaded 447    
    Comments  [Add]    
    Cited by others  12    

Recommend this journal